Using 2-input (Ach and Bch) operation function
Input the sensor detection signal into AcH and BcH of AMH -148 and inspect the lead cut length using the operation function (A -B). The operation result is compared and decided at a high -speed sampling rate of 1000 times/second. Furthermore, it is possible to find the maximum and minimum of the calculated value using the peak-hold and valley-hold functions.
Memorizing several pass/fail decision ranges using the pattern selection function
The pattern selection function can memorize 8 kinds of upper upper-limit, upper-limit, lower-limit, and lower lower-limit set values and hysteresis values, as well as 8 kinds of scaling values. The tolerance range can be instantly switched with the front switch This is very useful for flexible lines that contain multiple materials.
Power supply for sensors incorporated (Built in excitation)
Models WPM-1, AM-147 and AM-215A have an internal 12 VDC and 24 VDC power supply for external equipment. This power supply is useful when connecting a sensor with an internal amplifier. Using a direct setting function allows easy input of setting of decision values HH, HI, LO, and LL using the actual measured sensor detection data.
Deciding the clearance of piston ring at high speed
The sequential A/D conversion method enables decisions at a rate of 4000 times/second. This is very useful for environments with a short inspection process time.
Connect to CT, PT, DC Voltage divider, shunt resistor
For example, digital panel meter A6000 for AC measurement has standardized range for CT connection.This meter inputs 5A on secondry side of CT to enable scaling of any current value on the primary side.
The dustproof and waterproof structure allows washing from the front panel
Models WPM-1, ATC-217 conform to the IP66 standard. These models are best suitable for temperature, pressure, and weight measurements made in the HACCP process control.